# MMLU-Pro / 11704

task_id: 508f564a-ad36-5dfd-9fbd-c346ddc957d3
task_key: default--test--11704
task_revision_id: 1

{"category":"engineering","options":"['11.05m^2', '6.89m^2', '14.21m^2', '9.54m^2', '10.23m^2', '5.67m^2', '8.76m^2', '12.34m^2', '4.82m^2', '7.89m^2']","question":"Compute the surface area required in a heat exchanger to cool the fluid from 177°C to 77°C, carrying heat at the rate of 100W/K. The heat exchanger gains solar energy by irra-diation at the rate of 100W/m^2. Assume the value of trans-fer factor f as 0.9.","src":"stemez-HeatTransfer"}