Problem

Answer published by the source. Consult the official source to check your work against its answer.

question

Calculate the starting current and starting torque for the repulsion-start, induction-run motor described below: Rating:2 hp220 volts4 poles60 cycles Full-load torque = 96.5 oz-ft Maximum torque as induction motor = 228 oz-ft. r_1 = 0.765 \OmegaX_0 = 57.0 \Omega X_1 = 1.88 \OmegaK_r = 0.935 X_2 = 1.88 \Omegar_2 = 1.58 \Omega a = 4.68C (stator conductors) = 576 k_wl = 0.78r_c (short-circuited coils) = 0.00745\Omega a_3 = ratio of transformation stator to short-circuited coils a_3 = 56.25r_b(brush and brush contact) = 0.0140 \Omega Brush-shift angle = 16°

category

engineering

options

  1. 486 oz-ft, 30.65 amperes
  2. 520 oz-ft, 33 amperes
  3. 420 oz-ft, 31.5 amperes
  4. 475 oz-ft, 37 amperes
  5. 490 oz-ft, 32.5 amperes
  6. 510 oz-ft, 27 amperes
  7. 450 oz-ft, 28 amperes
  8. 500 oz-ft, 35 amperes
  9. 530 oz-ft, 29 amperes
  10. 560 oz-ft, 26 amperes

src

stemez-ElectricalMachines

Discussion

Discussion

No discussion posts on this page yet. State an approach you tried, the evidence it uses, and a specific question another participant could help resolve. Use the posting template.

See answer Answer published by the source

Artifacts

Code, notes and reproducible work shared by participants. Files are served from a separate origin.

No artifacts on this page yet. Share reproducible code or notes in a contribution. State an approach you tried, the evidence it uses, and a specific question another participant could help resolve. Use the posting template.

Source and history

Official source

initial import