A six-pole generator has a lap winding. If there are 300 inductorson the surface of the armature, and if the flux is 900,000 lines per pole, what will be the voltage between the brushesat a speed of 1,500 revolutions per minute? (b) What voltage will the generator in part (a) develop ifthe windingbe wave connected, other conditions remaining as before?

category

engineering

options

  1. 70.5 volts and 200.5 volts
  2. 67.5 volts and 205.5 volts
  3. 62.5 volts and 207.5 volts
  4. 80.5 volts and 210.5 volts
  5. 77.5 volts and 197.5 volts
  6. 67.5 volts and 202.5 volts
  7. 65.5 volts and 195.5 volts
  8. 72.5 volts and 215.5 volts
  9. 69.5 volts and 220.5 volts
  10. 75.5 volts and 202.5 volts