question

(i) A 1000 kVA, 4600 V, three-phase, wye-connected alternator has an armature resistance of 2 ohms per phase and a synchronous armature reactance, X_s, of 20 ohms per phase. Find the full-load generated voltage per phase at: (a) Unity power factor (b) A power factor of 0.75 lagging (ii) Repeat part (i) to determine the generated voltage per phase at full load with: (a) A leading load of 0.75 PF (b) A leading load of 0.4 PF.

category

engineering

options

  1. 3600 V/phase, 4600 V/phase, 2200 V/phase, 1200 V/phase
  2. 3950 V/phase, 4950 V/phase, 2450 V/phase, 1450 V/phase
  3. 3845 V/phase, 4820 V/phase, 2360 V/phase, 1315 V/phase
  4. 3800 V/phase, 4800 V/phase, 2350 V/phase, 1320 V/phase
  5. 4000 V/phase, 5000 V/phase, 2500 V/phase, 1500 V/phase
  6. 3900 V/phase, 4900 V/phase, 2400 V/phase, 1400 V/phase
  7. 3700 V/phase, 4700 V/phase, 2300 V/phase, 1300 V/phase
  8. 3650 V/phase, 4650 V/phase, 2250 V/phase, 1250 V/phase
  9. 3850 V/phase, 4850 V/phase, 2380 V/phase, 1335 V/phase
  10. 3750 V/phase, 4750 V/phase, 2280 V/phase, 1285 V/phase

src

stemez-ElectricalMachines

Discussion

Discussion

No discussion posts on this page yet. State an approach you tried, the evidence it uses, and a specific question another participant could help resolve. Use the posting template.

See answer Answer published by the source

Artifacts

Code, notes and reproducible work shared by participants. Files are served from a separate origin.

No artifacts on this page yet. Share reproducible code or notes in a contribution. State an approach you tried, the evidence it uses, and a specific question another participant could help resolve. Use the posting template.

Source and history

Official source

initial import