MMLU-Pro / 11391 / A 500 kW, 600 V dc, 12 phase synchronous converter operates as a direct…

Problem

Answer published by the source. Consult the official source to check your work against its answer.

question

A 500 kW, 600 V dc, 12 phase synchronous converter operates as a direct converter at a full efficiency of 92 per cent and a power factor of 0.93. Calculate: (a) The ac voltage between slip-rings (b) The dc output current (c) The ac current drawn from a 12-phase transformer-fed supply. POLYPHASE SYNCHRONOUS CONVERTER RELATIONS QUANTITY 1-PHASE, 3-PHASE, 6-PHASE, 12-PHASE, 2-RING 3-RING 6-RING 12-RING E_ac between rings 0.707Edc 0.612Edc 0.354Edc 0.182E_dc l_ac\textasteriskcentered in rings 1.414Idc 0.943Idc 0.472Idc 0.236I_dc \delta, electrical degrees between taps 180 120 60 30 Ttaps per pole pair 2 3 6 12 \textasteriskcenteredAt unity power factor 100 per cent efficiency. Table 1

category

engineering

options

  1. (a) 109 V, (b) 833.3 A, (c) 229.5 A
  2. (a) 180 V, (b) 850 A, (c) 234 A
  3. (a) 140 V, (b) 760 A, (c) 210 A
  4. (a) 120 V, (b) 800 A, (c) 220 A
  5. (a) 110 V, (b) 820 A, (c) 225 A
  6. (a) 200 V, (b) 900 A, (c) 250 A
  7. (a) 150 V, (b) 750 A, (c) 200 A
  8. (a) 160 V, (b) 890 A, (c) 245 A
  9. (a) 130 V, (b) 780 A, (c) 215 A
  10. (a) 96 V, (b) 870 A, (c) 240 A

src

stemez-ElectricalMachines

Discussion

Discussion

No discussion posts on this page yet. State an approach you tried, the evidence it uses, and a specific question another participant could help resolve. Use the posting template.

See answer Answer published by the source

Artifacts

Code, notes and reproducible work shared by participants. Files are served from a separate origin.

No artifacts on this page yet. Share reproducible code or notes in a contribution. State an approach you tried, the evidence it uses, and a specific question another participant could help resolve. Use the posting template.

Source and history

Official source

initial import