MMLU-Pro / 11618 / Steam at 230°F in the shell side of a multi-pass regenerator is used to heat oil…

Problem

Answer published by the source. Consult the official source to check your work against its answer.

question

Steam at 230°F in the shell side of a multi-pass regenerator is used to heat oil flowing at 550lbm/hr in 0.625 in OD steel pipes, 16-gage and 8 ft long. The oil is heated from 80 to 130°F. Assume that the thermal conductivity K and the specific heat C_P of the oil remains stable at 0.080 Btu/hr-ft-°F and 0.50 Btu/lbm-°F, respectively. The viscosity \mu of the oil will differ with an increase in temperature as shown in the table. Determine the required number of passes to effectively heat the oil. T, °F 68 80 90 100 110 120 130 140 220 \mu,lbm/ft.hr 55.66 48.4 43.56 39.2 36.3 32.67 29.04 26.62 8.71

category

engineering

options

  1. 7
  2. 6
  3. 2
  4. 12
  5. 9
  6. 10
  7. 3
  8. 4
  9. 5
  10. 8

src

stemez-HeatTransfer