A two-pole dc generator has an armature containing a total of 40 conductors connected in two parallel paths. The flux per pole is 6.48 × 10^8 lines, and the speed of the prime mover is 30 rpm. The resistance of each conductor is 0.01 ohm, and the current-carrying capacity of each conductor is 10 A. Calculate: (a) The average generated voltage per path and the generated armature voltage (b) The armature current delivered to an external load (c) The armature resistance (d) The terminal voltage of the generator.

category

engineering

options

  1. Average generated voltage per path and the generated armature voltage: 110 V, Armature current delivered to an external load: 12 A, Armature resistance: 0.08 Ω, Terminal voltage of the generator: 110.4 V
  2. Average generated voltage per path and the generated armature voltage: 130 V, Armature current delivered to an external load: 24 A, Armature resistance: 0.18 Ω, Terminal voltage of the generator: 125.7 V
  3. Average generated voltage per path and the generated armature voltage: 150 V, Armature current delivered to an external load: 18 A, Armature resistance: 0.25 Ω, Terminal voltage of the generator: 135 V
  4. Average generated voltage per path and the generated armature voltage: 129.6 V, Armature current delivered to an external load: 20 A, Armature resistance: 0.1 Ω, Terminal voltage of the generator: 127.6 V
  5. Average generated voltage per path and the generated armature voltage: 135.6 V, Armature current delivered to an external load: 22 A, Armature resistance: 0.15 Ω, Terminal voltage of the generator: 132.6 V
  6. Average generated voltage per path and the generated armature voltage: 160 V, Armature current delivered to an external load: 30 A, Armature resistance: 0.3 Ω, Terminal voltage of the generator: 151 V
  7. Average generated voltage per path and the generated armature voltage: 140 V, Armature current delivered to an external load: 25 A, Armature resistance: 0.2 Ω, Terminal voltage of the generator: 130 V
  8. Average generated voltage per path and the generated armature voltage: 125 V, Armature current delivered to an external load: 28 A, Armature resistance: 0.2 Ω, Terminal voltage of the generator: 119 V
  9. Average generated voltage per path and the generated armature voltage: 115 V, Armature current delivered to an external load: 10 A, Armature resistance: 0.12 Ω, Terminal voltage of the generator: 113.8 V
  10. Average generated voltage per path and the generated armature voltage: 120 V, Armature current delivered to an external load: 15 A, Armature resistance: 0.05 Ω, Terminal voltage of the generator: 120 V

src

stemez-ElectricalMachines

Discussion

Discussion

No discussion posts on this page yet. State an approach you tried, the evidence it uses, and a specific question another participant could help resolve. Use the posting template.

See answer Answer published by the source

Artifacts

Code, notes and reproducible work shared by participants. Files are served from a separate origin.

No artifacts on this page yet. Share reproducible code or notes in a contribution. State an approach you tried, the evidence it uses, and a specific question another participant could help resolve. Use the posting template.

Source and history

Official source

initial import